MRZP Master Correction

Haas A-Axis DWO Calibration · Setting 301 / 302
Live Calc
A Roto-vise setup
  1. Dial in the rotary along Z (shim if needed), then along Y.
  2. Mount the roto-vise to the rotary and dial it in concentric with the rotary.
  3. Put a 6" parallel in the roto-vise jaw and dial in the new 0°.
  4. With A jogged to the new 0°: Settings › Rotary › Set offsets › TC offset, then power cycle.
B DWO calibration
  1. Put the DWO ball gage in the vise on the 4th axis (or the roto-vise).
    .492
  2. Jog the probe over the ball and run the boss probing cycle on G54.
  3. Offsets › Work offset: subtract half the ball diameter (.492) from Z.
  4. Edit › Calibration › MRZP › 4. A, B, or C Single Axis Rough and Finish MRZP Set
  5. Run cycle 1 at 0°.
  6. Rotate the 4th axis to 30° and run cycle 2. (Angle can vary.)
  7. Rotate to the opposite 30° and run cycle 3. (Can vary; doesn't have to match.)
  8. Check the probe went back home in Z. If Z stayed low to the part, a cycle didn't register: run them again.
  9. Current Commands › Macros: copy #10122 and #10123.
  10. Settings › Machine Setup: enter those as the Y and Z masters.
  11. Rotate the 4th axis back to 0°.
  12. Probe the ball with the boss cycle on G54 (probe Z in the cycle).
  13. Offsets › Work offset: subtract .492 from Z again.
  14. List Program › DWO Accuracy Test and run it.
  15. Offsets › G154 P53: copy the Y and Z error.
  16. Enter the new masters from the calculator below in Settings › Machine Setup (or adjust by hand: ±.001 at first, ±.0002 to fine tune).
  17. Re-run the DWO Accuracy Test until G154 P53 is under .0004. loads the new masters and clears P53.
Last good setup: Y -12.9831 · Z -22.2566 (after MRZP: -12.9839 / -22.263)
01 · Current Master Values From Settings Page
Distance from A-axis center to Y machine zero (in)
Distance from A-axis center to Z machine zero (in)
02 · DWO Accuracy Test Results G154 P53 Values
Use 45° or 90° for best resolution
Angle must be non-zero and ≠ 360°·n
From offsets page after test run
From offsets page after test run
Enable if a previous correction made the error worse — Haas convention can vary by machine
03 · Suggested New Master Values Awaiting Input
New Setting 301 (Y Master)
— in
New Setting 302 (Z Master)
— in
εY (Y centerline error): —
εZ (Z centerline error): —

Math Reference

Let s = sin(A), c = cos(A), k = 1 − c P53_Y = k·εY + s·εZ P53_Z = −s·εY + k·εZ Solving 2×2: εY = (k·P53_Y − s·P53_Z) / (2k) εZ = (s·P53_Y + k·P53_Z) / (2k) New Master = Old Master + ε (flip sign if convention reversed)

Workflow: Probe ball center into G54 (X/Y boss + Z minus radius) → run DWO Accuracy Test at chosen A angle → enter P53 values above → apply suggested values to Settings 301 / 302 → re-test to verify.

Sign sanity: If after applying the correction your P53 values grow instead of shrink, flip the "Invert Correction Sign" toggle and re-apply.